PVC Edge banding Specifications

  1. Color: Slight color variations are possible from dye lot to dye lot.
  2. Finishes: ​Available in Gloss, Matt & SF. Finish must be smooth and free of defects at a distance of 3 feet from the observer. Material either has UV inhibitors directly in the resin or has a ​UV topcoat.
  3.  Interior Use: Only for interior use and not to be exposed to temperatures above 150°F.
  4. Primer: Backside is 100% covered with a visible primer for proper bond.
  5. Maintenance: Clean surface with warm soapy water and wipe clean.


Tolerances

Edge Banding Width

Width mm

Tolerance mm

12 – 54

± 1.00

Edge Banding Thickness

Width mm

Tolerance mm

0.4 - 0.7

± 0.05

0.8 - 1.5

± 0.10

1.6 - 2.0

+ 0.20

2.1 - 3.0

+ 0.25


Storage

PVC Edge Banding tape is resistant to rot and may therefore be stored at room temperature (64°F to 68°F) in a room that is weatherproof and protected from direct sun light for a virtually unlimited period.


Warranty

Using accepted industry standards, colors, woodgrains, and patterns have been individually matched and cross-referenced for the best suitable match. Color variation beyond the manufacturers' control may occur in individual resin batches. The manufacture rs' warranty and liability for the bond, color match, and surface finish; extend only to the replacement value of the specific edge banding material. It is the customer's sole responsibility to determine that the bond and color match are acceptable for production before use.


Fire and Explosion Data

Flash Point: 390 - 700 Degrees Celsius

Flammable Limits

​Upper Explosion Limit: N/A

​Lower Explosion Limit: N/A

Auto Ignition Temperature: N/A

Suitable Extinguishing Media: Carbon Dioxide Blanket, Water Spray, Dry Powder, Foam

Special Fire Fighting Procedures: Full-face self-contained breathing apparatus (SCBA) used in positive pressure mode should be worn to prevent inhalation of airborne contaminants.

Unusual Fire / Explosion Hazards: May emit Hydrogen Chloride (HCL) or Carbon Monoxide (CO), Oxides of Nitrogen (NOx), other hazardous materials, and smoke are all possible.


Reactive Data

Product Stability: Very Stable

Reactivity conditions: Under normal usage none. However, harsh chemicals such as Ketones, Toluene’s, Acetones and other similar solvents may melt or react with the surface finish.

Hazardous Decomposition Implications: Hydrochloric acid can be formed if product is heated to the point of burning and then in the presence of water may form Hydrochloric Acid.


First Aid

Inhalation: Remove the affected user to a well-ventilated area.

Eye Contact: Irritant only on contact, bathe area affected.

Ingestion: Under normal condition, there is no probable route of ingestion.

Skin Contact: Non-Toxic


Disposal and Storage

Waste Disposal: Landfill

Recycle: Product can be reprocessed for re-use.

Environmental Toxicity: Adverse ecological impact is not known or expected under normal use.